Matomo

EL-550 Ozone Water Sensor: Compact UV Absorption Monitor

The EL-550 is a compact ozone water sensor combining detection and processing in a single all-in-one housing. Using UV absorption technology, it measures dissolved ozone from 0-50 mg/L (default) with ranges up to 150 mg/L available. This cost-effective monitor features analog outputs (0-1V, 0-10V, or 4-20mA), digital display with rotary selection, and operates from 5-40°C water temperature. Ideal for industrial water treatment, research laboratories, and aquaculture applications requiring reliable ozone monitoring.

Download Brochure
acniti EL-550 dissolved ozone sensor for industrial and research applications
Back to: Ozone Water Sensors
General
1 Model name Industrial Ozone Water Sensors: Compare EL-550, EL-610 & CX-100 II
2 Model number sensor_o3_water_concentration
3 Technology UV Absorption Method
LiquidMetricImperial
4 Minimum flow / minute 0.1 Liter 0.0 Gallon
5 Maximum flow / minute 3.0 Liter 0.8 Gallon
6 Minimum flow / hour 3.0 Liter 0.8 Gallon
7 Maximum flow / hour 180 Liter 48 Gallon
8 water temperature minimum 5 ℃ 41 ℉
9 water temperature maximum 40 ℃ 104 ℉
AmbientMetricImperial
10 Ambient temperature minimum 5 ℃ 41 ℉
11 Ambient temperature maximum 40 ℃ 104 ℉
12 Relative humidity minimum 0 %
13 Relative humidity maximum 90 %
ElectricalMetricImperial
14 Unit phase Ø voltage 100-220V ±10% AC50/60Hz
15 Unit power consumption 50VA 0.07 HP
16 Wetted parts Synthetic quartz, PTFE, PFA
17 Pump pressure setting 0.3 MPa (G) or less
Pump
Dimensions & weightMetricImperial
18 Dim. (w) x (d) x (h) 220 x 105 x 150 mm 8.7 x 4.1 x 5.9 inch
19 weight 2.2 Kg 4.9 lbs.
20 HS code 9027-9090 9027-9090

Key features

  • All-in-one housing: Detection and processing units are combined, resulting in a compact and space-saving design.
  • Cost-effective: By limiting functions to the essentials, both initial and operational costs are reduced.
  • Clear display options: Display of ozone concentration, sensor light intensity, and span value via a rotary switch facilitates monitoring and maintenance.


Measuring ranges

In units mg/L with a continuous measuring ineterval

  • 0-10.00
  • 0-20.0
  • 0-30.0
  • 0-40.0
  • 0-50.0 (acniti default)
  • 0-60.0
  • 0-100
  • 0-120
  • 0-150

Sampling method

Water pressure intake or suction by sampling pump is not included in the sensor. Order a sampling pump separetely here

Display function

Available (selection among ozone concentration, light intensity of the sensor or span by a rotary switch) When measuning ozone concentration, minimum figure of the indicator is as follows.

  • in case of 10 mg/L => 0.01 mg/L
  • in case of 20 - 60 mg/L => 0.1mg/L (acniti default)
  • in case of 100-150 mg/L => 1 mg/L

Analogue output

  • Voltage output 0-1V or 0-10 V DC
  • Current output 4-20mA DC (insulated)

Back to: Ozone Water Sensors