Slideshow Items

  • 残留塩素計 ECLG-35

The ECLG‑35 Residual Chlorine Meter is a high-precision, reagent-free sensor designed for continuous monitoring of free residual chlorine in drinking water and industrial water systems. Utilizing a 3-electrode pulse voltammetry method, the ECLG-35 provides accurate and stable measurements without the need for chemical reagents.

Why choose the ECLG-35?

The sensor features an advanced automatic cleaning system, combining bead flow and electrolytic cleaning to maintain consistent sensitivity and minimize drift over time. With a measuring range of 0.00-3.00 mg/L, high repeatability (±2% FS), and a fast response time (T90 ≤ 1 minute), the ECLG-35 ensures reliable chlorine control under varying water conditions.

This unit is equipped with automatic temperature compensation and a built-in thermistor, ensuring stable performance across a wide pH and conductivity range. Installation is flexible: wall-mounting is standard, or optional pipe-mounting on Ø50 mm tubing.

Priority to safe, clean water

With reagent-free operation, built-in cleaning, and excellent measurement stability, the ECLG-35 ensures accurate, long-term chlorine control, eliminating the need for routine maintenance or consumables—ideal for utilities and facilities where a safe and clean water supply is a top priority.

The Residual Chlorine Meter ECLG-35 is ideal for use in water treatment plants, distribution networks, buildings, hospitals, hotels, and the food or pharmaceutical industries. The ECLG‑35 provides peace of mind in water safety and regulatory compliance. All while operating without consumables or complex maintenance procedures.

Typical Applications

  • Drinking water production and distribution
  • On-site water supply (hospitals, schools, hotels)
  • Storage tanks and reservoirs
  • Industrial water disinfection (food, pharma)
  • Real-time quality monitoring without consumables

Technical specifications

ParameterDetails
Measurement principle3-electrode pulse voltammetry
Measuring range0.00 – 3.00 mg/L (free residual chlorine)
Repeatability±2 % FS + 1 digit (3 mg/L range)
Linearity±5 % FS + 1 digit
Zero/Span drift≤ ±1 % FS (zero), ≤ ±10 % FS/month (span)
Response time (T90)≤ 1 minute
Temperature compensationAutomatic (built-in thermistor)
Power supply100–240 V AC, 50/60 Hz (~20 VA)
Sample water conditionspH: 5.8–8.6, Conductivity: 5–100 mS/m, Temp: 0–40 °C
Installation methodWall mount (standard), optional 50 mm pipe mount
Operating temperature-10 – 45 °C, RH ≤ 90 % (non-condensing)
Storage temperature-20 – 60 °C

If you need a durable, low-maintenance chlorine meter that delivers long-term accuracy and efficiency, the ECLG‑35 is the wise choice.

残留塩素計

  • 化学薬品は必要ない
  • 遊離残留物のみを測定する
  • 自動センサークリーニング
  • 広い測定範囲
  • 優れた再現性
  • 迅速な対応
  • 堅牢な設置オプション

規格

  • 製品名ECLI-35
    製品番号ECLI-35
    仕様表ECLI-35
    • ECLG-35とECLI-35の主な違いは、表示分解能と測定精度にある。
    • 測定範囲0~3mg/L
    • Display Resolution: Lower precision with 0.1mg/L minimum display increment (displays to tenths)Display Resolution: Lower precision with 0.1mg/L minimum display increment (displays to tenths)
    • ECLI-35はECGI-35より経済的である。
  • 製品名ECLG-35
    製品番号ECLG-35
    仕様表ECLG-35
    • ECLG-35とECLI-35の主な違いは、表示分解能と測定精度にある。
    • 測定範囲0.00~3.00mg/L
    • 表示分解能:0.01mg/L刻みの高精度(100分の1まで表示)
    • The ECGI-35 is more expensive than the ECLI-35