The HS series are submersible single-phase portable pumps. The shaft-mounted agitator prevents "Air Lock" that tends to take place on vortex or semi-vortex pumps*. The rubber/resin-made stand protects the floor surface from scratching. The HSZ-series with a single float switch reduces power consumption and extends operating life.
The benefit of a vortex impeller over a channel impeller is the minimized risk of clogging. The vortex impeller creates a revolving mass of water which forms a whirlpool. A whirlpool is a funnel shaped opening is created downward from the water surface. It can be developed by water flowing out of a small opening in the bottom of a basin, a reservoir or by a pump. Impellers creating this Vortex are called vortex impellers. The benefit of a vortex impeller over a channel impeller is the minimized risk of clogging. A Vortex impeller is also a better choice when the pumped liquid has a high content of sand. The efficiency of a pump with a vortex impeller is typically lower than a pump with a channel impeller.
Table technical specification
# | Liquid specifications | 50 Hz | 60 Hz | Head |
---|---|---|---|---|
1 | Maximum pump capacity liter | 225 | 197 | |
2 | Maximum pump capacity Gallons | 59 | 52 | |
3 | Liter per minute @ head | 180 | 189 | 3   Meter |
4 | Gallon per minute @ head | 48 | 50 | 10   Feet |
# | Electrical specifications | - | - | - |
5 | Electric phase ⌀ voltage | 1 Ø 115 VAC or 1 Ø 220 VAC | ||
6 | Power consumption | 400 watts | ||
7 | Pump house material | Cast Iron, Ductile Cast Iron(HSD) Urethane Rubber , High Chrome Cast Iron(HSD) 403 Stainless Steel Aluminum alloy 304 Stainless Steel Silicon Carbide NBR (Nitrile Butadiene Rubber) | ||
8 | Power cord length | 5 meters Meter | ||
# | Connections | Metric | Imperial | - |
9 | Water outlet | 50 mm or 2" | ||
# | Dimensions | Metric | Imperial | - |
10 | Dim. (w) x (d) x (h) mm | 184 x 241 x 328 | 7 x 9 x 13 | |
11 | Weight | 11.5 Kg | 25 lbs. | |
12 | HS code | 8413.7010 |